Independent third-party testing
Men’s Performance+ · Lot HGP250821

Tested.
Verified.
Published.

This production lot was independently tested for heavy metals, microbiological contaminants and label-claim accuracy. Here are the results, without hiding the numbers.

Laboratory
Ethos Analytics
Report completed
September 7, 2025
Sample ID
25EA0829-004
Serving size tested
1,440mg

How to read this page. Heavy-metal concentration is reported in parts per million (ppm). The daily-intake figures below convert those concentrations using the report’s 1.44g serving size. The percentages compare that intake with the recommended oral daily limits shown on the laboratory report. Results apply specifically to sample 25EA0829-004 from lot HGP250821; the certificate records the submitted sample name as “13212 - Horny Goat Weed.”

All reported safety screens passed
4/4 heavy-metal results and 7/7 microbiological results met the report’s specifications.
Final status: Pass

Heavy metals.
The actual numbers.

Testing used ICP-MS under USP <233>. Each result passed the daily limit stated on the laboratory report.

ArsenicAs · ICP-MS
✓ Pass
0.212
ppm in tested powder
Calculated intake per 1.44g serving0.305µg
0.305µgRecommended limit: 15µg/day
2.0% of the recommended daily limit
CadmiumCd · ICP-MS
✓ Pass
0.104
ppm in tested powder
Calculated intake per 1.44g serving0.150µg
0.150µgRecommended limit: 5µg/day
3.0% of the recommended daily limit
LeadPb · ICP-MS
✓ Pass
0.241
ppm in tested powder
Calculated intake per 1.44g serving0.347µg
0.347µgRecommended limit: 5µg/day
6.9% of the recommended daily limit
MercuryHg · ICP-MS
✓ Pass
<LOQ
below the 0.010ppm quantification limit
Maximum implied intake per 1.44g serving<0.0144µg
<0.0144µgRecommended limit: 15µg/day
Less than 0.1% of the recommended daily limit

Purity checked.
Label claim checked.

The certificate also reports microbiological screening and a quantitative check of the formula’s L-Phenylalanine claim.

Label claim profile · HPLC
31.77mg

L-Phenylalanine measured per serving against a 30mg-per-serving specification. Testing completed September 7, 2025.

Microbiological analysis
TestResultSpecificationStatus
Total aerobic plate<20 CFU/g<100,000 CFU/gPass
Coliform<20 CFU/g<100 CFU/gPass
Yeast<20 CFU/g<1,000 CFU/gPass
Mold<20 CFU/g<1,000 CFU/gPass
Escherichia coliNegative/10gNegative/10gPass
SalmonellaNegative/10gNegative/10gPass
Staphylococcus aureusNegative/10gNegative/10gPass

Independently tested.

This report was conducted by Ethos Analytics and completed on September 7, 2025. The analysis covered heavy metals, microbiological contaminants and the stated L-Phenylalanine label claim for lot HGP250821.